Features
Technical Specifications
- NBVI-18WFR/NBVO-18
- Cooling Capacity 17.401 (4.436-18.084) Btu / h
- Cooling Capacity 5.1 (1.3-5.3) kWatt
- Heating Capacity 17.742 (4.436-18.084) Btu / h
- Heating Capacity 5.2 (1.3-5.3) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14.825) - Cooling
- Pdesign 5.1 kW
- Energy Class A++
- SEER 6.7
- Energy Consumption 266 kWh / year
- Heating Middle Zone
- Pdesign 3.3 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.155 kWh / year
- Heating Warm Zone
- Pdesign 3.6 kW
- Energy Class A+++
- SCOP 5.3
- Energy Consumption 951 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 7.4 (1.2-7.9) Α
- Current Input Heating 6.2 (1.0-6.6) Α
- Power Input Cooling 1.67 (0.28-1.8) kW
- Power Input Heating 1.4 (0.22-1.5) kW
-
Air Flow Volume
(High / Med / Low) 770/680/600 m³ / h -
Sound Power Level Indoor Unit
(Quiet / Low / Medium / High / Turbo) 24/34/38/42/52 db(A) - Sound Power Level Outdoor Unit 52 db(A)
- Sound Power Level Indoor Unit 57 db(A)
- Sound Power Level Outdoor Unit 62 db(A)
- Dehumidifying Volume 1.6 L/h
- Dehumidifying Volume 38.4 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” - 1 / 2”
- Power Supply Wire Outdoor 3 × 1.5 / 16 Α
- Signal Wires 5 × 1.0 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 900x225x310 mm -
Dimensions
Outdoor Unit
(WxDxH) 715x280x537 mm - Net Weight Indoor / Outdoor 10.0/23.0 kg
- Refrigerant / Quantity R32 / 540 g
- Operation Temperature Range Outdoor Unit Cooling -16~49 °C
- Operation Temperature Range Outdoor Unit Heating -15~30 °C
- NBVI-24WFR/NBVO-24
- Cooling Capacity 24.566 (6.142-25.249) Btu / h
- Cooling Capacity 7.2 (1.8-7.4) kWatt
- Heating Capacity 24.566 (6.142-27.978) Btu / h
- Heating Capacity 7.2 (1.8-8.2) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14.825) - Cooling
- Pdesign 6.7 kW
- Energy Class A++
- SEER 6.5
- Energy Consumption 359 kWh / year
- Heating Middle Zone
- Pdesign 5.7 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.950 kWh / year
- Heating Warm Zone
- Pdesign 7.0 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 1.859 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 10.0 (1.0-12.0) Α
- Current Input Heating 9.5 (1.0-11.0) Α
- Power Input Cooling 2.2 (0.23-2.76) kW
- Power Input Heating 2.2 (0.23-2.53) kW
-
Air Flow Volume
(High / Med / Low) 1.150/1.010/870 m³ / h -
Sound Power Level Indoor Unit
(Quiet / Low / Medium / High / Turbo) 22/30/34/38/41 db(A) - Sound Power Level Outdoor Unit 51 db(A)
- Sound Power Level Indoor Unit 63 db(A)
- Sound Power Level Outdoor Unit 66 db(A)
- Dehumidifying Volume 2.5 L/h
- Dehumidifying Volume 60.0 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” - 5 / 8”
- Power Supply Wire Outdoor 3 × 2.5 / 25 Α
- Signal Wires 5 × 2.5 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 1.082x233x330 mm -
Dimensions
Outdoor Unit
(WxDxH) 900x350x700 mm - Net Weight Indoor / Outdoor 14.0/39.0 kg
- Refrigerant / Quantity R32 / 1.300 g
- Operation Temperature Range Outdoor Unit Cooling -16~49 °C
- Operation Temperature Range Outdoor Unit Heating -15~30 °C
Advantages
Λειτουργία ECO
With ECO Mode, the air conditioner is automatically set to run at the lowest possible consumption and then automatically switches off after 8 hours. So you can achieve even greater reductions in the operating costs of the unit, while enjoying the ideal conditions you desire.
Powerful Self-Cleaning
With a touch of a button on the remote control your air conditioner cleans itself! The process only takes up a few minutes. When it is finished, the unit is ready to be used again, clean from bacteria and fungi, providing fresh and clean air.
Automatic Louvers' Movement
Dispense cold/warm air at max range with automatic horizontal movement louvers
A+++ Energy Class
Excellent heating operation for maximum energy savings
High Density Air Dust Filter
The exquisite filter optimizes the filtering effect by 40%.
24- hour Timer
Set the unit to start and stop automatically in a 24h period.
Turbo Mode
This function gives more impulse to the cooling and heating operation for a time period contribute to the room's direct cooling or heating
Sleep Mode
With the Sleep Mode, the airconditioner adjusts the room temperature for perfect sleeping conditions and energy saving.
Smart Defrosting
Energy saving and improved heating efficiency with intelligent defrosting. Intelligent defrosting is achieved only by sensors that control the need and duration of the defrosting process.
Two-way Draining
Both left and right sides of the indoor unit are possible for drainage hose connection, for easier installation
More
Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
Refrigerant Leak Detection
The indoor unit will display an error code "EC" and it will automatically stop when diagnose refrigerant leakage to protect the compressor from overheating
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
R32 Refrigerant
The R32 ecological refrigerant, with 68% lower global warming potential, does not adversely affect the ozone layer, while contributes in reducing global warming and maintenance costs.
Media Library for Nobu (NBV)
User Manual - Energy Labels - High Resolution Photos
NOBU News
Make now your registration to NOBU newsletter, to learn everything about your favorite products