Toro air conditioning series with Triple Action Filter, Active Carbon Filter & Wi-Fi!

  • Active Carbon Filter for easy removal of every trace of dust in your place
  • Triple Action Filter for a healthy & pleasant atmosphere
  • Wi-Fi Ready for energy savings and ultimate comfort
  • Antibacterial Protection for an absolutely clean atmosphere
  • Powerful Self-Cleaning function for excellent performance and protection of the unit
  • NBTR-VI32-09WFR / NBTR-VO32-09
  • Cooling Capacity 9.000 (1.706-9.895) Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 25/31/37/43 db(A)
  • Cooling Capacity 2.60 (0.50-2.90) kWatt
  • Heating Capacity 10.000 (1.706-10.578) Btu / h
  • Heating Capacity 2.80 (0.50-3.10) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A++
  • SEER 6.15
  • Energy Consumption 149 kWh / year
  • Heating Middle Zone
  • Pdesign 2.2 kW
  • Energy Class A+
  • SCOP 4.10
  • Energy Consumption 752 kWh / year
  • Heating Warm Zone
  • Pdesign 2.4 kW
  • Energy Class A++
  • SCOP 5.08
  • Energy Consumption 663 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 4.2 (0.6-7.0) Α
  • Current Input Heating 5.6 (1.0-7.0) Α
  • Power Input Cooling 800 (100-1300) W
  • Power Input Heating 750 (100-1400) W
  • Air Flow Volume
    (Turbo / Hi / Med / Low)
    560/497/482/358 m³ / h
  • Sound Power Level Outdoor Unit 51 db(A)
  • Sound Power Level Indoor Unit 57 db(A)
  • Sound Power Level Outdoor Unit 61 db(A)
  • Dehumidifying Volume 1.2 L/h
  • Dehumidifying Volume 28.8 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” - 3 / 8”
  • Power Supply Wire Outdoor 3 × 1.5 / 10 Α
  • Signal Wires 5 × 1.0 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    750x200x285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    730x285x545 mm
  • Net Weight Indoor / Outdoor 7.5/25.0 kg
  • Refrigerant / Quantity R32 / 530 g
  • Operation Temperature Range Outdoor Unit Cooling 16~47 °C
  • Operation Temperature Range Outdoor Unit Heating -15~32 °C
  • NBTR-VI32-12WFR / NBTR-VO32-12
  • Cooling Capacity 12.000 (2.730-11.942) Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 26/33/39/44 db(A)
  • Cooling Capacity 3.50 (0.80-3.50) kWatt
  • Heating Capacity 12.000 (3.412-12.284) Btu / h
  • Heating Capacity 3.50 (1.00-3.60) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 3.2 kW
  • Energy Class A++
  • SEER 6.10
  • Energy Consumption 184 kWh / year
  • Heating Middle Zone
  • Pdesign 2.4 kW
  • Energy Class A+
  • SCOP 4.07
  • Energy Consumption 826 kWh / year
  • Heating Warm Zone
  • Pdesign 2.7 kW
  • Energy Class A++
  • SCOP 4.82
  • Energy Consumption 784 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.0 (0.7-7.8) Α
  • Current Input Heating 6.0 (1.5-8.0) Α
  • Power Input Cooling 1090 (100-1600) W
  • Power Input Heating 970 (300-1600) W
  • Air Flow Volume
    (Turbo / Hi / Med / Low)
    560/497/482/358 m³ / h
  • Sound Power Level Outdoor Unit 52 db(A)
  • Sound Power Level Indoor Unit 53 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Dehumidifying Volume 1.4 L/h
  • Dehumidifying Volume 33.6 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” - 3 / 8”
  • Power Supply Wire Outdoor 3 × 1.5 / 10 Α
  • Signal Wires 5 × 1.0 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    750x200x285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    730x285x545 mm
  • Net Weight Indoor / Outdoor 8/25 kg
  • Refrigerant / Quantity R32 / 600 g
  • Operation Temperature Range Outdoor Unit Cooling 16~47 °C
  • Operation Temperature Range Outdoor Unit Heating -15~32 °C
  • NBTR-VI32-18WFR / NBTR-VO32-18
  • Cooling Capacity 18.000 (4.095-18.426) Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 30/36/41/47 db(A)
  • Cooling Capacity 5.25 (1.20-5.40) kWatt
  • Heating Capacity 19.000 (4.095-19.790) Btu / h
  • Heating Capacity 5.50 (1.20-5.80) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 6.57
  • Energy Consumption 283 kWh / year
  • Heating Middle Zone
  • Pdesign 4.4 kW
  • Energy Class A+
  • SCOP 4.02
  • Energy Consumption 1.535 kWh / year
  • Heating Warm Zone
  • Pdesign 5.5 kW
  • Energy Class A+++
  • SCOP 5.40
  • Energy Consumption 1.426 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.5 (0.6-8.8) Α
  • Current Input Heating 9.7 (1.2-9.7) Α
  • Power Input Cooling 1660 (90-2000) W
  • Power Input Heating 1490 (200-2200) W
  • Air Flow Volume
    (Turbo / Hi / Med / Low)
    850/750/657/564 m³ / h
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 58 db(A)
  • Sound Power Level Outdoor Unit 64 db(A)
  • Dehumidifying Volume 1.8 L/h
  • Dehumidifying Volume 43.2 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” - 1 / 2”
  • Power Supply Wire Outdoor 3 × 1.5 / 10 Α
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    900x225x310 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800x315x545 mm
  • Net Weight Indoor / Outdoor 12/35 kg
  • Refrigerant / Quantity R32 / 1.280 g
  • Operation Temperature Range Outdoor Unit Cooling 16~47 °C
  • Operation Temperature Range Outdoor Unit Heating -15~32 °C
  • NBTR-VI32-24WFR / NBTR-VO32-24
  • Cooling Capacity 24.000 (4.777-24.909) Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 31/37/43/48 db(A)
  • Cooling Capacity 7.00 (1.40-7.30) kWatt
  • Heating Capacity 24.000 (3.071-24.226) Btu / h
  • Heating Capacity 7.00 (0.90-7.10) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 6.7 kW
  • Energy Class A++
  • SEER 6.89
  • Energy Consumption 341 kWh / year
  • Heating Middle Zone
  • Pdesign 5.7 kW
  • Energy Class A+
  • SCOP 5.11
  • Energy Consumption 1.940 kWh / year
  • Heating Warm Zone
  • Pdesign 7.0 kW
  • Energy Class A+++
  • SCOP 5.25
  • Energy Consumption 1.867 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 12.5 (0.7-13.2) Α
  • Current Input Heating 11.5 (1.2-11.6) Α
  • Power Input Cooling 2200 (130-3000) W
  • Power Input Heating 1960 (200-2700) W
  • Air Flow Volume
    (Turbo / Hi / Med / Low)
    1150/1010/902/795 m³ / h
  • Sound Power Level Outdoor Unit 58 db(A)
  • Sound Power Level Indoor Unit 60 db(A)
  • Sound Power Level Outdoor Unit 65 db(A)
  • Dehumidifying Volume 2.3 L/h
  • Dehumidifying Volume 55.2 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” - 5 / 8”
  • Power Supply Wire Outdoor 3 × 2.5 / 16 Α
  • Signal Wires 5 × 2.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.082x233x330 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    900x350x700 mm
  • Net Weight Indoor / Outdoor 15/45 kg
  • Refrigerant / Quantity R32 / 1.440 g
  • Operation Temperature Range Outdoor Unit Cooling 16~47 °C
  • Operation Temperature Range Outdoor Unit Heating -15~32 °C

The golden coating of the new Nobu indoor and outdoor unit ensures maximum protection for your air conditioner, boosting its performance, extending its lifetime and improving the air quality in the room. Thanks to the anti-corrosion composition of the hydrophilic coating on the outdoor unit, the resistance to corrosive elements such as rain increases is improved, while the golden coating on the indoor unit prevents the bacteria from reproducing and spreading in space, creating a healthy and comfortable environment.

The exquisite filter optimizes the filtering effect by 40%.

A smart sensor is located on the remote control. When the iFeel function is activated the set temperature synchronizes with the smart sensor.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation

Set the unit to start and stop automatically in a 24h period.

With the Sleep Mode, the airconditioner adjusts the room temperature for perfect sleeping conditions and energy saving.

This function gives more impulse to the cooling and heating operation for a time period contribute to the room's direct cooling or heating

Dispense cold/warm air at max range with automatic horizontal movement louvers

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

The indoor unit will display an error code "EC" and it will automatically stop when diagnose refrigerant leakage to protect the compressor from overheating

The R32 ecological refrigerant, with 68% lower global warming potential, does not adversely affect the ozone layer, while contributes in reducing global warming and maintenance costs.

Οι ανεμιστήρες των εσωτερικών και εξωτερικών μονάδων και ο συμπιεστής, έχουν αναβαθμιστεί με τεχνολογία All DC Inverter. Με αυτόν τον τρόπο, ο συμπιεστής μπορεί να αλλάξει χωρητικότητα ανάλογα με τις ανάγκες του εσωτερικού περιβάλλοντος και να παρέχει τέλειες συνθήκες στον χώρο σας

Media Library for Toro Air Conditioner

User Manual - Energy Labels - High Resolution Photos

NOBU News

Make now your registration to NOBU newsletter, to learn everything about your favorite products