New Floor Standing Unit for an equable airflow at every place!

  • Excellent performance even under the most difficult weather conditions with excellent heating performance at -15oC
  • Effective aiconditioning any time you wish thanks to the Turbo mode
  • Equable airflow in every spot of the room for ideal temperature conditions

Πόσα Btu/h χρειάζομαι;


South Greece
North Greece
Residential
Commercial
Single
Double
No
Yes
Under 400 m.
Over
Btu / h
  • NBFS-48IDU / NBFS-48ODU
  • 41.626 (23.884 - 46.744)
  • Energy Class A
  • Noise Level Indoor Unit (Low / Hi) 46 / 54 db(A)
  • Cooling Capacity Range 12.2 (7.0 - 13.7) kWatt
  • Heating Capacity 41.969 (22.179-47.770) + 10.236 Btu / h
  • Heating Capacity 12.3 (6.5 - 14.0) + 3.0 kWatt
  • Cooling
  • Energy Class A
  • SEER 3.21
  • Heating
  • Energy Class A
  • COP 3.62
  • Voltage / Frequency / Phase 380 / 50 / 3 V / Hz / Ph
  • Current Input Cooling 8.2 (3.7-10.9) Α
  • Current Input Heating 7.4 (3.4-11.9) + 4.6 Α
  • Power Input Cooling / Heating 3.000 W
  • Air Flow Volume 1.700 m³ / h
  • Noise Level Outdoor Unit 59 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 3/8” | 5/8’’
  • Power Supply Wire Outdoor 3 x 16 Α
  • Signal Wires 5 x 2.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    600 x 313 x 1.868 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    970 × 370 × 790 mm
  • Net Weight Indoor / Outdoor 59 / 70 kg
  • Refrigerant R410A/ 3.200g
  • Operation Temperature Range Outdoor Unit Cooling 13~43 °C
  • Operation Temperature Range Outdoor Unit Heating -15~34 °C

This function gives more impulse to the cooling and heating operation for a time period contribute to the room's direct cooling or heating

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Set the unit to start and stop automatically in a 24h period.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

With the Sleep Mode, the airconditioner adjusts the room temperature for perfect sleeping conditions and energy saving.

The indoor unit will display an error code "EC" and it will automatically stop when diagnose refrigerant leakage to protect the compressor from overheating

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Both left and right sides of the indoor unit are possible for drainage hose connection, for easier installation

If the temperature sensor has any problem, a protection code will display on the air conditioner's screen. The air condition unit will stop operating until the problem will be fixed.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation